VX 1014 In-house amplifier
Category : Distribution amplifier Home Line
- Zinc pressure cast housing - home line
- Return path amplifier and diplex-filter modular
- ICS option modular
- Damping adjustment and equaliser adjustment interruption-free with Q-step switcher
Downstream |
|
with US-module VX 101-0650 |
|
Frequency range | 85...1006 MHz (without US-module) |
Return loss | ≥ 18 dB (-1,5 dB/Oct.) |
Gain | 15 dB (±0,5 dB) |
Frequency response | typ. ± 0,5 dB (max. ± 0,8 dB) |
cable simulator downstream | 0/5/10 dB (Jumper) |
Attenuator downstream | 0...15 dB (Q-Step 1dB step size) |
Equalizer downstream | 0...22,5 dB (Q-Step 1.5 dB step size) |
output level CC 101 channels flat | CTB / 66 dB ≥ 97 dBµV, CSO / 66 dB ≥ 95 dBµV |
Noise figure | typ. 6 dB (max. 8 dB) |
Test point downstream output | -20 dB (directional coupler) |
Upstream |
|
with US-module VX 101-0650 |
|
Frequency range | 5...65 MHz |
Return loss | ≥ 18 dB ≥ 40 MHz 18 dB -1,5dB/Okt. |
Gain | 10 dB (± 0,75 dB) |
Frequency response | typ. ± 0,5 dB (max. ± 0,8 dB) |
Attenuator upstream output | 0...15 dB (Q-Step 1dB step size) |
noise figure | < 6 dB |
output level DIN - IMA 2 | typ. 108 min. 106 dBµV |
output level DIN - IMA 3 | typ. 114 min 112 dBµV |
ICS Option | (slot for receiver EN60728-14) |
Ingress Control Switch (ICS) | 0/6/40 dB |
General data |
|
RF connectors | F |
Impedance | 75 Ω |
Supply voltage | 230 V AC |
Power consumption max. | < 6 W |
Ambient temperature | -20...+55 °C |
Protection class | IP 20 |
EMC | EN50083-2 |
Surge protection RF Ports | 2 kV (1,2/50 μs pulse EN61000-4-5) |
Dimensions (width x height x depth) | 163 x 90 x 47 mm |