VX 57 A Universal line amplifier, remote supplied

Category : Distribution amplifier Compact Line

The VX 57 A is a Universal line remote feeding amplifier that has 2 active output and slots for feeding channels. In addition, it has an incorporated VX 58 ASC module. All settings are adjusted via OH 41 or LMT (laptop).

  • Two active outputs
  • All settings with OH 41 A handset or LMT (laptop) when using a HMS-transponder
  • Interface for NMS-function
  • Diplex filters and splitter / tap modules pluggable
  • Return channel amplifier pluggable
  • ASC module VX 58
  • Downstream

    Inputs 1 pcs.
    Input measurement socket 20 dB
    Input return loss >20 dB
    Frequency range downstream 47/85...1006 MHz
    Gain downstream 2x 39,5 dB (with XM 51 A (4/4 dB))
    Noise figure downstream ≤6,5 dB
    Attenuator downstream 0...15 dB (0,1 dB-steps)
    Equalizer downstream 0...15 dB (0,1 dB-steps)
    Interstage attenuator downstream 0/5/10 dB
    Interstage equalizer downstream 0/6/9 dB
    Output level 1 2x 111 dBµV (CENELEC 42 channels, flat, at CSO/CTB >60 dB)
    Output level 2 2x 114 dBµV (CENELEC 42 channels, 6 dB slope, at CSO/CTB >60 dB)
    Output test point 20 dB
    Output return loss >20 dB
    Output splitter 1 pcs.

    Upstream

    Frequency range upstream 5...30/65 MHz (depending on diplexers)
    Gain upstream 26 dB
    Noise figure upstream ≤10 dB
    Attenuator upstream input 0...30 dB
    Attenuator upstream output 0...30 dB
    Equalizer US 0...10 dB
    Output level 4 116 dBµV
    ICS, US 0/-8/-45 dB (switchable)
    Upstream test point 20 dB

    Connectors

    PG11 4 pcs.

    General data

    Operating voltage AC 27...65 V (50/60 Hz)
    Power consumption 33/31 W (with/without transponder)
    Remote power <8 A
    Screening factor Class A, EN 50083-2
    Dimensions (width x height x depth) 261x215x100,4 mm
    Operating temperature range -20...+50 °C
    Lightning protection 6 kV (EN61000-4-5, 1,2/50 µs pulse)