VX 2030 204 Thumbnail Image VX 2030 204 Building CATV Amplifier 1,2 GHz

Category : Distribution amplifier Value Line

The VX 2030 is a location feeding in-house amplifier with a frequency range up to 1.2 GHz. It has an active output and a measuring socket on the input and output. Diplex filter and return path amplifier are grouped together on a module (VX201-xxx) and available in the versions 65 MHz, 85 MHz and 204 MHz. All settings are done without interruption with Q-step switch or jumper. In addition, a high pass filter XE-xx can be plugged in the return path to influence the ingress influences.

  • High output level up to 1.2 GHz, with low power consumption
  • Active single output
  • Measuring socket for input and output
  • All settings (gain, slope etc.) by rotary switch and Jumper
  • Diplex filters, return amplifier pluggable on one module
  • Optional - receiver according to EN 60728-14 for ICS-settings
  • Optional - pluggable high pass filter at the return path channel
  • Low power input <18 W

 

TECHNACAL DATA

Downstream

Frequency range 85...1218 MHz
Gain 30 dB (±1 dB)
Ripple ≤ ± 0,8 dB
Noise figure <7,5 dB @ 1 GHz, <8,0 dB @ 1,2 GHz
Output level 112 dBµV (CENELEC 41 Ch. (CSO/CTB ≥ 60 dB), flat)
Output level 107 dBµV (110 Ch/QAM 256, flat, BER <1 E-9)
Output level 106 dBµV (all QAM (138 x 256 QAM), EN60728-3-1, flat)
Input cable simulator 0/5/10 dB (Jumper)
Input attenuator 0...15 dB (Rotary switch 15 Steps)
Step size 1 dB
Input equalizer 0...30 dB/ 1218 MHz Drehpunkt (Rotary switch 15 Steps)
Step size 2 dB
Interstage equalizer (Slope) 0/2/4/6/8 dB (Jumper)
Interstage attenuation 0/2/4/6 dB
Test point -20 dB

Upstream

Frequency range 5...65 MHz
High pass filter pluggable (optional) 15 MHz (WISI - XE 04 0150)
Gain 29 dB (±1 dB)
Ripple ± 0,5 dB
Noise figure < 6,5 dB
Output level 110 dBµV (6 x 256 QAM)
Interstage attenuator 0...15 dB (Rotary switch 15 Steps)
Step size 1 dB
Interstage equalizer 0/2/4/6/8 dB (Jumper)
Output attenuator 0/10 dB (Jumper)
Output equalizer 0/6 dB (Jumper)
Ingress control switch (optional) nach ICS EN 60728-14
Test point -20 dB

General data

RF connectors PG 11/F
Impedance 75 Ω
In/Output return loss 5...40 MHZ >16, >40MHz -1,5dB Oktave, >12
Supply voltage 230 V AC ±10 %
Power consumption < 18 W
Ambient temperature -20...+55 °C
Protection class IP 67
EMC EN50083-2
Surge protection RF Ports 2 kV (1,2/50 μs pulse EN61000-4-5)
Dimensions W x H x D 232 x 158 x 86 mm