LX 25 X XDXX RFoG Upstream Receiver

Category : Optopus optical receivers 19-inch

Upgrading your network infrastructures to OBI-free (Optical Beat Interference) RFoG networks with this active upstream receiver. Use up to 32 output ports (or cascade them to reach higher port numbers) and eliminate issues instantly with the dedicated upstream receivers. Each of these ports provides an input power measurement in real time and can be shut off if necessary (testing purposes or subscriber service shutdown). That's why the LX 25 enables network providers to heal existing OBI-infected RFoG networks without any need to swap existing end user equipment. The solution will work with any upstream wavelength and laser mode. OPTOPUS and its OBI-free RFoG technology offer network providers a complete future-proof concept, while opening the doors for new FTTx deployments.

  • Converts existing RFoG networks to OBI free solutions without exchange of fiber nodes
  • Remote optical input power reading and switch off functionality per port via SNMP and WEB
  • Two BC input ports
  • Electrical upstream test port
  • Local or remote powered version available
  • All connectors on the front

 

Upstream Receiver

Optical input power +3...-10 dBm
Receiving wavelength 1260...1630 nm (except 1550 +/- 10nm)
Impedance 75 Ω
Frequency range 5 (15)...204 MHz
Output level 70...85 dBµV (OMI=15%/ch)
Frequency response ≤ ±0,5 dB
Output attenuator 0...40 dB (0,5 dB steps)
Schräglage 0...8 dB (0,5 dB steps)
Return loss >20 dB (-1 dB/Oct.) min. 16 dB
Equivalent input noise max. 7 pA/√Hz
Integrated upstream transmitter (optional)
Laser type Uncooled isolated DFB laser
Wavelength 1270...1610 nm (CWDM)
Output power 3 dBm
RIN < -145 dBHz-1
OMI setting range 3...8 % (75 dBµV measured @ TP), (step 1 %)

General optical parameters

Optical return loss >45 dB
Insertion loss DS (COM-> Out FN) typ. <14 dB
Insertion loss US (Out FN-> PD_US) <1 dB
Entkopplung (COM->PD_US) >60 dB

Connectors

Downstream 1x LC/APC or 1x SC/APC
Upstream 1x LC/APC or 1x SC/APC
Test point 1x F
Node 8x,16x or 32x ports

General data

Supply voltage 230 V AC / 27...65 V AC / 48V DC
Power consumption <8 W
Operating temperature -20...+55 °C
EMC EN50083-2
Dimensions (width x height x depth) 425 x 43 x 250 mm

Monitoring / Management

Attenuator 0...40 dB (0,5 dB steps)
Schräglage 0...8 dB (0,5 dB steps)
Port 1-32 Upstream On/Off
Port 1-32 Upstream opt. receiving power dBm